Halogen Free, Low Smoke, Highly Flame Retardant, Identificat

Update: 14-10-31 13:34       View:
  • Brand:  
  • unit 
  • Price: 0RMB
  • Promotion:0RMB
Introduction
  Description

MTVLD(DIN)halogen free, low smoke, highly flameretardant marker tags are made by means of bombardment and cross-linking of theenvironmentally friendly polyolefin with high energy electron beams. Markertags are non-adhesive that can be used to identify EMU for high-speed rails,subways, motor train units, submarines and aerospace. Market tags are attachedon large cables and wire bundles with cable ties and keep permanentidentification.  

Features
  • Halogen free low smoke emitting materials, ideal for identifying motor train unit, rail transit, aerospace and naval vessels
  • Not necessary to disconnect the electrical return circuit when installing the identification maker labels 
  • Using the binding wire, easy to handle
  • Temperature resistance, rated temperature 125°C
  • Highly flame retardant, low toxicity index, meets international locomotive standards
  • RoHS compliant, meets SONY SS-00259
  • Permanent identification, not melting in high temp., not turning fragile in low temp., resistant to scrape, rub, abrasion
  • Computer-printable, any character and logo are easy to design.
Rated Temperature
Continuous operating temperature: -55°C~125°C/-67°F~257°F
Max. storage and transportation temp.: ≤50°C /122°F

Standards
Material standards: ASTM D 2671/DIN5510-2
British/French smoke toxicity standards: BS 6853/NF F 16-101
Color code soundness: SAE-AS 81531 and MIL-STD-202F/215J


Structure




Dimension
 
Order description Width Gmm L Lengthmm Printed Characters Cable ODmm
Height G Length l
MTVLD-10.4-45/4/ 10.4 45 10.4 25 5.08~12.7
MTVLD-10.4-53/4/ 10.4 53 10.4 33 5.08~12.7
MTVLD-10.4-64/4/ 10.4 64 10.4 44 5.08~12.7
MTVLD-10.4-76/6/ 10.4 76 10.4 56 5.08~12.7
MTVLD-10.4-90/6/ 10.4 90 10.4 70 5.08~12.7
MTVLD-15.0-45/4/ 15.0 45 15.0 25 12.7~19.1
MTVLD-15.0-53/4/ 15.0 53 15.0 33 12.7~19.1
MTVLD-15.0-64/4/ 15.0 64 15.0 44 12.7~19.1
MTVLD-15.0-76/6/ 15.0 76 15.0 56 12.7~19.1
MTVLD-15.0-90/6/ 15.0 90 15.0 70 12.7~19.1
MTVLD-20.3-45/4/ 20.3 45 20.3 25 19.1~25.4
MTVLD-20.3-53/4/ 20.3 53 20.3 33 19.1~25.4
MTVLD-20.3-64/4/ 20.3 64 20.3 44 19.1~25.4
MTVLD-20.3-76/6/ 20.3 76 20.3 56 19.1~25.4
MTVLD-20.3-90/6/ 20.3 90 20.3 70 19.1~25.4
MTVLD-25.4-45/4/ 25.4 45 25.4 25 ≥25.4
MTVLD-25.4-53/4/ 25.4 53 25.4 33 ≥25.4
MTVLD-25.4-64/4/ 25.4 64 25.4 44 ≥25.4
MTVLD-25.4-76/6/ 25.4 76 25.4 56 ≥25.4
MTVLD-25.4-90/6/ 25.4 90 25.4 70 ≥25.4
 


Physicochemical & Electrical Performance
Performance Indicators Test Method
 Typical properties Unit States
Tensile Strength Mpa Unaged ≥10.3 ASTM G 154, MIL-DTL-23053E
ISO 37, 500mm/min
175°C, 168h, ISO 188
Heat aged/ After fluids/UV aged ≥6.9
Elongation at break % Unaged ≥200
Heat aged/ After fluid ≥100
Secant Modulus Mpa Unaged <173 ASTM D 882
Voltage Withstand V Unaged / After aged 2500V, No breakdown in 60 sec. IEC 243, ASTM G 154
175°C, 168h, ISO 188
Dielectric Strength MV/m Before aged ≥19.7
Heat aged/ After fluid/ UV aged ≥15.8
Volume Resistivity Ω.cm Unaged ≥1014 IEC 93
Dielectric constant - Unaged - ASTM 150
Water Absorption - Unaged ≤1.0 ASTM 570, 23°C, 24h
Bare Copper Corrosion - Unaged No corrosion 23°C,Rh 95±5%, 24h
175°C,16h
Heat Shock - Unaged No cracks, flowing, dripping Wind to the specified mandrel, 225°C,4h
Cold Flexibility - Unaged No cracks Wind to the specified mandrel, -30°C, 1h
Flammability - Unaged DIN 5510,S3 DIN 5510-2
Smoke Density - Unaged ≤0.017 DIN 5510-2
Toxcity Index - Unaged ≤1 BS 6853:1999
 
More Products